EasyManuals Logo

HIKVISION Pyronix EURO 46 V10 User Manual

HIKVISION Pyronix EURO 46 V10
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
48
EURO 46 V10 Programming Manual
Appendix 3 - SMS Commands
Setting the system via SMS text command
Example SMS command send: Description: Example SMS command
response:
123456 Set A 123456 = User Code. Set A = Will set the Enforcer in area A. Final Set; area A
123456 Set ABCD 123456 = User Code. Set ABCD = Will set the Enforcer in
area A, B, C and D.
Final Set; area ABCD
NOTE: If no areas are specified then all areas will set (default). The default will be area A.
Unsetting the system via SMS text command
Example SMS command send: Description: Example SMS command
response:
123456 Unset A 123456 = User Code. Unset A = Will unset area A. Unset; area A
123456 Unset ABCD 123456 = User Code. Unset ABCD = Will unset the area A,
B, C and D.
Unset; area ABCD
NOTE: If no areas are specified then all areas will unset (default). The default will be area A.
Setting with inputs omitted via SMS text command
Example SMS command send: Description: Example SMS command
response:
123456 Set A
Omit 4
123456 = User Code. Set A Omit 4 = Sets area A and will omit
input number 4.
Input omit; area A Input 04
Forced Set; area A
123456 Set A Omit Kitchen 123456 = User Code. Set A Omit Kitchen= Sets area A and
will omit the input that is called Kitchen.
Input omit; area A Kitchen 04
Forced Set; area A
Omitting inputs via SMS text command
Example SMS command send: Description: Example SMS command
response:
123456 Omit 6 123456 = User Code. Omit 6 = Input number 6 will be omitted
on the next setting procedure.
Input Omit; area A Input 06
123456 Omit Garage 123456 = User Code. Omit Garage = The input called
Garage will be omitted on the next setting procedure.
Input Omit; area A Garage 06
NOTE: The name of the output has to be one word and spelled exactly as written in the panel, such as: ‘Garage Door’ is not
acceptable. It has to be written as ‘Garage-Door’ in the panel and the respective command will be ‘Garage-Door’.
Checking the System Status via SMS text command
Example SMS command send: Description: Example SMS command
response:
123456 Status 123456 = User Code. Status Area A Unset No Faults
Area B Unset No Faults
Area C Unset No Faults
Area D Unset No Faults
Operating the User Automation Outputs via SMS text commands
Example SMS command send: Description: Example SMS command
response:
123456 Output 1 On 123456 = User Code. User Output 1 turns on. OUTPUT 1 ON
123456 Output Garage-Door
On
123456 = User Code output Garage-Door on = Turns output
named as Garage-Door on.
OUTPUT Garage-Door ON
123456 Output Garage-Door
Off
123456 = User Code output Garage-Door off = Turns output
named as Garage-Door off.
OUTPUT Garage-Door OFF