EURO 46 V10 Programming Manual
9. ‘Enter Location’ will be displayed. Enter the location of
the keypad and press .
10. Press b or d to select another device address
to program (0-9) or press the key to return to the
Engineer Menu.
Programming Readers for Set Point or Unset Only: Assign Keypads/Readers
1. Press b or to scroll to ‘ASSIGN KEYPADS/
READERS’. Press .
2. Press b or d to select the address. Press .
3. ‘Type’ will be displayed. Press 1 to select
‘Reader’. Press
4. ‘Reader is’ will be displayed. Press for ‘Set Point’ or
press 1 for ‘Unset Only’ Press .
5. ‘Set Point Sets’ will be displayed. Select the area(s).
Press .
6. ‘Set Point Unsets’ will be displayed. Select the area(s).
Press .
7. ‘Set Point In’ will be displayed. Enter the area in which
the keypad is situated and press .
8. ‘Set Point Description’ will be displayed. Press to
enter the name and location if required.
9. ‘Enter Name’ will be displayed. Enter the name of the
keypad and press .
10. ‘Enter Location’ will be displayed. Enter the location of
the keypad and press .
ASSIGN KEYPADS/
READERS?
Address
[1]
Type
Keypad [0]
Reader is
Set Point [0]
Set Point Sets
[01ABCD]
Set Point Unsets
[01ABCD]
Set Point In
[01ABCD]
Set Point
Description?
Enter Name
Device 01
Enter Location
_
Enter Location
_