29
EURO 46 V10 Programming Manual
Wireless Dual Frequency Menu:
This option is used to view and troubleshoot the Dual Frequency operation of your system:
Channel – Displays which channel your control panel is operating on (this will be either 01 or 02).
Channel Reason – Displays the reason why the panel last switched from one channel to another.
SF/DF Status – Displays whether the control panel is currently operating in Single (SF) or Dual (DF)
Frequency mode.
PLEASE NOTE: The panel will only operate in dual frequency mode if ALL peripherals support dual
frequency (having even one SF device will default the whole system into SF mode).
First SF device – Displays the first single frequency device learnt on to the system (if there is one),
once deleted it will display the next single frequency device and so forth. If there are none it will
display; “All Devices DF”.
Wired Devices?
View Inputs
This option views the status of all wired inputs: Open, Close, Tamper, and Fault.
Endstation Inputs:
The status of the inputs will be shown. C = Closed. O = Open. F = Fault, T = Tamper. The resistance
reading can also be shown by pressing for any of the above for statuses.
ZEM Inputs:
Choose the ZEM address from [0] to [7] to view the input status.
Keypad Inputs:
Choose the keypad address from [0] to [5] to view the input status.
Reader Inputs:
Choose the reader address from [1] to [5] to view the input status.
View PSUs?
This option allows diagnostics of the power supply information for the PSU on the control panel, as
well as all the additional peripheral devices, such as ZEM or Output modules that have a PSU on
board.
Endstation PSU
End station voltage readings are displayed = Voltage: 13.7V.
ZEM PSUs
Choose the ZEM address from [0] to [3] to read the PSU voltage readings.
OP Mod PSU
Choose the Output Module address from [0] to [1] to read the PSU voltage readings.
Keypad Volts
Choose the Keypad address from [0] to [9] to read the keypad voltage.
Reader Volts
Choose the Reader address from [0] to [5] to read the reader voltage.
Calibration?
Enter the ‘Security Code’ to gain access to this menu. This function permits calibration of the control
panel PSU voltage, using a calibrated meter.