Figure 7-8 Draw Area
8.
Click Save.
9.
Repeat above steps to set other regions.
10.
Set arming schedule. See
Set Arming Schedule .
11.
Set linkage method. See
Linkage Method Sengs .
7.2.8 Set
Unaended Baggage Detecon
Unaended baggage detecon is used to detect the objects le over in the predened area.
Linkage methods are triggered aer the object is le and stays in the area for a set me period.
Steps
1.
Go to Conguraon → Event → Smart Event Unaended Baggage Detecon .
2.
Check Enable.
3.
Oponal: Click Lock to lock PTZ control to prevent the interrupon from other PTZ related acon
during conguraon.
Normally, the PTZ control is automacally locked when you enter the conguraon interface.
You can manually resume the lock when the countdown is over.
4.
Adjust the live image to the desired scene by using PTZ control
buons.
5.
Draw detecon area.
1) Select a Region No.. Up to 4 regions can be set.
2) Click
Detecon Area.
3) Click on the live image to draw the boundaries of the
detecon area, and right click to
complete drawing.