Handheld Thermography Camera · User Manual
Go to Palettes Settings ( ) to set the palette.
Purpose:
Set the alarm rules and the device will alarm when the temperature
triggers the rule.
Steps:
1. Go to Palettes Settings ( ) from the main menu.
2. Tap on the icons to select an alarm rule type.
3. (Optional) Press the △ and ▽ to select between upper limit
and lower limit.
4. Press the ◁ and ▷ to adjust the rule temperature.
Set the alarm temperature, and the
device alarms when target temperature
is higher than rule temperature.
Set the alarm temperature, and the
device alarms when target temperature
is lower than rule temperature.
Set the alarm temperature section (e.g.,
90°C - 150°C), when target temperature
is within the section (e.g., 100°C), the
device alarms.
Set the alarm temperature section (e.g.,
90°C - 120°C), when target temperature
is without the section (e.g., 70 °C or
125° C), the device alarms.
5. Press to exit the setting interface.