Note
The Uninterpretable Power Supply (UPS) is required.
The re system (NC and COM, normally closed when powering o) is connected with the lock
and the power supply in series. When an re alarm is triggered, the door remains open. In
normal
mes, NC and COM are open.
Figure 4-7 Device Wiring
Figure 4-8 Wiring Diagram
DS-K1T341C Series Face Recognion Terminal User Manual
21

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-K1T341CMF and is the answer not in the manual?

HIKVISION DS-K1T341CMF Specifications

General IconGeneral
TypeFace recognition terminal
Product colorBlack, Silver
Cards capacity3000 cards
Event capacity150000
Access code reader-
Authentication typeAccess chip/card, Face recognition
Face recognition distance0 - 2 m
Face recognition duration0.2 s
Access chip/card reader typeContact
International Protection (IP) codeIP65
Operating system installedLinux
Screen shapeFlat
Display diagonal4.3 \
Maximum resolution272 x 480 pixels
Touchscreen technologyCapacitive
Total megapixels2 MP
Ethernet LAN data rates10, 100 Mbit/s
Power consumption (typical)10 W
Operating temperature (T-T)-30 - 60 °C