Hilti PS 1000 X-Scan
tips & tricks
V 1.0 I 05/2011
0,


0,


0,
0,
0,
Scanning beams and columns
The reinforcement in beams and columns may be located very close to the edges.
As the scanner should never be lifted away from the surface when a scan is in progress, i.e. all
4 wheels must stay in contact with the surface at all times, sheets of a suitable material should
be positioned so that they project beyond the edges of the surface to be scanned. Objects
positioned close to the edge of a beam or column may be indicated less clearly than objects
positioned further from the edge due to the weaker signal received.
The thickness of the sheet must be taken into account when interpreting the readings from the
scan.
Transferring data from the scanner to the monitor
Scan data can be transferred from the scanner to the monitor in various ways.
1.) The PSA 50 / 51 data cable can be used to transfer data between the monitor and the
scanner. This feature is not available with the Hilti PS 1000-B X-Scan.
2.) Alternatively, scan data can be saved on an SD card (PSA 95) and transferred directly to a
PC or to the monitor unit using the PSA 96 card reader.
Transferring data from the scanner to a PC
To transfer scan data from the scanner to a PC, you require an SD card (PSA 95) and a
PSA 96 card reader.
• First insert the SD card in the memory card slot on the scanner.
All scan data will then be copied automatically to the SD card from the scanner’s internal
memory.
The card reader can then be connected to the USB interface on the PC and the data
subsequently transferred.
Caution: To avoid data loss, always make sure that the scanner is switched off before
inserting or removing the SD card.
Tips & tricks
Scanning on rough surfaces
When the scanner is moved over a rough surface, the distance between the scanner and the
surface beneath doesn’t remain constant. The position and depth readings obtained are thus
inaccurate. Measurement errors of this kind can be avoided by placing a thin sheet of suitable
material (e.g. wood, cardboard, etc.) on this rough surface.
The thickness of the sheet must be taken into account when interpreting the scan.
Question and Answer IconNeed help?

Do you have a question about the Hilti PS 1000 X-Scan and is the answer not in the manual?

Hilti PS 1000 X-Scan Specifications

General IconGeneral
BrandHilti
ModelPS 1000 X-Scan
CategorySecurity Sensors
LanguageEnglish

Summary

Scanning on Rough Surfaces

Scanning Beams and Columns

Transferring Data to Monitor

Transferring Data to PC

Detecting Steel Rebairs Beside PVC Pipes

Marking an Object

Marking Objects in Quickscan Mode (Method 2)

Describes marking objects using outside edges in Quickscan mode.

Using Raw Scan Data

Marking Objects in Quickscan Mode

Detecting Objects in a Second Layer

Locating Pre- and Post-Tensioning Tendons

Drilling Through-holes Without Hitting Reinforcement

Calibrating Detection Results

Plausibility Test

Detecting and Interpreting Plates

Interpreting Scans of Hollow-Core Concrete Components

Interpreting Scans of Profile Metal Sheet Composite Decks

Interpreting Scans of Floor Heating Systems

Interpreting Scans of Pre- and Post-Tensioning Tendons

Interpreting Insulating Layers

Scanning and Interpreting Objects at an Angle

Tips for Analyzing Multiple Layers

Using the Scanner Without the Grip

Wall/Corner Accessibility

Related product manuals