Monitoring Energy Consumption
25
Refer to "Analysis" (p. 26) for analysis methods.
Make input channel settings on the CH screen.
1
2
Setting Example
Channel: P1, Input: Count, Count Mode: Add
Use the scaling function to display values in kWh units.
Cond: Dec, Unit: kWh, 1 Pulse = 20u [kWh],
1 kWh=50000 Pulse
The display range changes automatically when scal-
ing is used.
(+/ -)
(E/P/T/G/M/k/ (blank) /m/
u/n/p/f/a)
Select digit position
Select digit value
Select
Apply
3 Start and Stop Measurement
Press the START/STOP key.
The specified length of data is recorded
and stored on the CF card.
Recording stops thirty days after start-
ing.
To interrupt recording, press the START/STOP key
again.