Analysis
30
Data saved by the LR8431-20 can be confirmed on the File screen. It is stored on
the CF Card or USB flash drive as follows. The numbers in the file names are auto-
matically generated sequentially.
View CF Card/USB flash drive Contents
WAVE0001.MEM
(Waveform data, binary)
WAVE0001.CSV
(Waveform data, text)
(Waveform data folder)
DATA
HIOKI_LR8431
CONF0001.SET(Settings data)
(Settings data folder)
CONFIG
Moves to child folderMoves to parent folder File selection Use to delete or rename a file
MEASUREMENT
PICTURE
(Numerical calculation
results folder
)
(
Screen image folder)
MEAS0001.CSV
(Numerical calculation results)
SCR00001.BMP
(Screen image)
12-07-01
(the folder name is
the date of file creation)
Analyzing HiLogger Data on a Computer
Recorded data can be analyzed and HiLog-
ger settings can be changed using a com-
puter running the supplied application
program. Not only waveforms, but also nu-
merical values and alarm output states can
be monitored in real time. Measurement
data from up to five LR8431-20 HiLoggers
can be collected by one computer using
USB connections. To use the Logger Utility,
connect a USB cable after setting the [USB
Mode] setting on the [System] screen to
[USB Communication].
To access the HiLogger's CF card from a com-
puter, connect a USB cable after setting the
[USB Mode] on the [System] screen to [USB
Drive].