39
position plus 5º.
4-3-8-4 Outdoor fan
The outdoor fan speeds except single speed motor can be changed according to outdoor ambient
temperatures.
3-7-6 4-way valve
State: It is electrified in heating.
Switchover: When initially powered on for heating, the 4-way valve is activated immediately.
In the change from cooling to heating, it needs an interval of 50 seconds for the 4-way valve to
change over from being interrupted to being activated.
3-8 The super function (option)
In cooling mode, when you press the SUPER button by remote control, the unit will operate for 15
minutes with the following setting:
a. The set temperature is 16;
b. The fan speed with highest speed;
c. The compressor runs with high frequency.
3-9 Dehumidifying mode
The dehumidifying mode is illustrated as follows:
Dehumidifying area I: Operation at the frequency in the range (3060Hz) according to Dt (T
indoor
ambient
-T
set
).
Dt()
f(Hz)
0