Heating:
EL
5m 7.5m 10m 15m 20m 25m 30m 35m 40m 45m 50m
9K/12K/18K 1.0
—
0.97 0.94 0.91 ——
—— —
——
—
24K 1.0
—
0.99 0.98 0.97 0.96 0.95
——
——
—
36K 1.0
—
0.99 0.98 0.97 0.96 0.95
——
——
—
48K —— 1.0 0.96 0.94 0.91 0.88 0.85 0.82 0.78 0.75 0.72
60K
—— 1.0 0.99 0.98 0.97 0.95 0.93 0.90 0.87 0.84 0.80
The correction factor of height between indoor unit and outdoor unit
Hight difference 10m 20m 30m
Factor 0.03 0.1
0.23
In order to ensure correct unit selection, consider the fartest indoor unit.
NOTE
1.
2.
Be sure to minimize lenght of connection pipes in order to optimize performance. In the case that the
outdoor unit is intalled higher or lower than the indoor unit, it is necessary to apply height correction
factor additionaly to length correction factor to calculate cooling/heating. If outdoor unit is higher,
correction should be applied to cooling capacity, if outdoor unit is lower, correction should be apply to
heating capacity.
Data above is assuming a height difference between indoor and outdoor of 0m.
Model