Troubleshooting
Regarding the indicator lamps (continued)
• When the interior portion has become overheated, for safety purposes, 
the projector is automatically shut down, and the indicator lamps may also be 
turned off. In such a case, disconnect the power cord, and wait at least 45 minutes. 
After the projector has sufciently cooled down, please make conrmation of the 
attachment state of the lamp and lamp cover, and then turn the power on again.
NOTE
POWER 
indicator
LAMP 
indicator
TEMP 
indicator
Description
Blinking
In Red
or
Lighting
In Red
Turned
off
Lighting
In Red
There is a possibility that the interior portion 
has become heated.
Please turn the power off, and allow the projector to cool down at least 
20 minutes. After the projector has sufciently cooled down, please make 
conrmation of the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air lter dirty?
• Does the peripheral temperature exceed 35°C?
• Is the projector used at an altitude of about 1600 m or 
higher? If the projector is used at an altitude of about 
1600 m or higher, set FAN SPEED of the SERVICE 
item in the OPTION menu to HIGH 
(
58)
.
Lighting
In Red
Turned
off
Turned
off
The lens door is not opened properly.
One of the followings has been happened.
• 
The lens door is not opened properly, when the projector 
is turned on.
• 
The lens door position is shifted, while the projector is working.
Restart the projector, after conrming that there is nothing 
that the lens door hits while opening or closing.
Lighting
In Green
Simultaneous
blinking in Red
It is time to clean the air lter.
Please immediately turn the power off, and clean or 
change the air lter referring to the section “Cleaning 
and replacing the air lter”. After cleaning or changing 
the air lter, please be sure to reset the lter timer. 
After the remedy, reset the power to ON.
Lighting
In Green
Alternative
blinking in Red
There is a possibility that the interior portion 
has become overcooled.
Please use the unit within the usage temperature 
parameters (5°C to 35°C).  
After the treatment, reset the power to ON.
Blinking In 
Green for 
approx. 3 
seconds.
Turned
off
Turned
off
At least 1 Power ON schedule is saved to the 
projector.
Please refer to Schedule Settings section of User’s 
Manual - Network Guide.