Do you have a question about the Hitachi E-162SN and is the answer not in the manual?
Specifies compatible outdoor units for R410A SET-FREE series multi-pipe connecting kits.
Instructions for transporting the product to the installation location before unpacking.
Verify part quantities and ensure no foreign materials are present before installation.
Details for horizontal and vertical installation, including minimum straight pipe lengths and inclinations.
Instructions for connecting liquid piping, including size specifications and insulation methods.
Critical safety notes for refrigerant piping, including leak checks, pressure tests, and insulation.
Specifies compatible outdoor units for R410A SET-FREE series multi-pipe connecting kits.
Instructions for transporting the product to the installation location before unpacking.
Verify part quantities and ensure no foreign materials are present before installation.
Details for horizontal and vertical installation, including minimum straight pipe lengths and inclinations.
Instructions for connecting liquid piping, including size specifications and insulation methods.
Critical safety notes for refrigerant piping, including leak checks, pressure tests, and insulation.
This document is an installation manual for Hitachi Multi-Kits, specifically for models E-102SN, E-162SN, E-242SN, and E-302SN. It provides essential information for the proper installation and handling of these kits, which are designed for R410A SET-FREE series outdoor units.
The Multi-Kits serve as multiple pipe connecting kits, facilitating the connection of refrigerant piping between outdoor units and indoor units in R410A SET-FREE series air conditioning systems. They include various components such as branch pipes for both gas and liquid lines, insulation for these lines, reducers for gas lines, expanders for liquid lines, and tape for securing insulation. The manual details the correct procedures for piping connection, including specific pipe sizes and installation positions, to ensure optimal system performance and safety.
Models Covered:
Applicable Outdoor Units:
Piping Connection Sizes (End of Multi-Kits): The manual provides detailed diagrams for each model (E-102SN, E-162SN, E-242SN, E-302SN) illustrating the finished pipe end sizes for both gas and liquid lines. These diagrams show various inner diameters (ID) and outer diameters (OD) at different points of the branch pipes, indicating where cuts should be made to match the connecting pipe sizes.
Air Tight Test Pressure:
Recommended Insulation Thickness:
Piping Size for Liquid Piping (2HP or smaller units, piping length 15m or longer):
Minimum Depth for Brazing (B):
Installation Position:
Piping Connection:
Safety Precautions:
The manual primarily focuses on installation and does not detail specific maintenance features for the Multi-Kits themselves. However, it emphasizes proper installation practices that contribute to the long-term reliability and performance of the overall air conditioning system, thereby reducing the need for corrective maintenance.
Key points related to system integrity and longevity:
Post-Installation Recommendation:
| Type | Remote Control |
|---|---|
| Model | E-162SN |
| Compatible Brand | Hitachi |
| Power Source | Battery |
| Number of Batteries | 2 |
Loading...