EasyManua.ls Logo

Hitachi G370 - Page 24

Hitachi G370
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Number Item Description
1 Controllers Controller 1 (left) and
Controller 2 (right).
2 Front end module N/A
3 CTL ALM LED Red: Controller can be
removed.
Blink red: Failure with the
power supply unit of the
controller.
Amber: LAN reset switch
was pressed.
4 BACKUP STTS LED Green: Power restoration in
progress following power
outage.
Fast blink green: Restoring.
Slow blink green: Restoring,
or sequential shutdown in
progress.
5 CTL WARN LED Amber blink one time:
Failure with fan 0.
Amber blink two times:
Failure with fan 1.
6 Cache ash memory N/A
7 LAN-RST switch Use only when instructed
by customer support.
8 LAN port Maintenance LAN port (left)
and user LAN port (right).
9 Uninterruptible power
supply (UPS) port
N/A
10 ALARM LED (for cache ash
memory)
Red: Cache ash memory
can be removed.
11 Backup module N/A
12 STATUS Green: Charging of the
battery in the backup
module is complete.
Blink green: Battery in the
backup module is charging
or discharging.
CBSL controller rear panel LEDs
Chapter 2: System controllers
Hitachi Virtual Storage Platform G350, G370 Hardware Reference Guide 24