3. Operation Method
10
A16381H9HL
3.7 Icon Description
The status of the remote controller is displayed on the operation screen.
NOTES:
•
It may not be displayed depending on the type of outdoor unit or indoor unit you are using.
•
No. Icon Description
A schedule timer is set.
The current time has not been set. Schedule timer operation is not possible.
The off timer is set.
The operation lock is set.
Displayed when using the central controller. Control through the wired remote
controller may be restricted depending on the settings of the central controller.
The FrostWash cycle is due to be run. Refer to Page 34 for details on
FrostWash.
It is time to clean the air filter.
A/C Air-conditioning operation is performed.
Vent.
THEX Vent.
Auto Vent.
Norm. Vent.
Ventilation, automatic ventilation, total heat ventilation, and normal ventilation
are operating. These icons appear only when compatible ventilation equipment
is installed.
In Rotation operation. This icon appears only when multiple systems are
installed and the Rotation operation is set.
In backup operation when abnormality occurs.
The standby refrigerant systems operate when abnormality occurs.
This icon appears only when multiple systems are installed and the backup
operation is set.
In backup operation in high load.
temperature, the standby refrigerant systems start to operate.
This icon appears only when multiple systems are installed and the backup
operation is set.
**
o
C
Displays the room temperature. (*1)
SAG Elevating grille is not positioned correctly.
Temporary Emergency operation is in progress.
Setback
When setback operation is enabled and the card key is removed (when no one is
present). (*2)
Purging In night purge progress.
Setback aborted Setback is aborted.
24-hour ventilation 24-hour ventilation is in progress.
Humidifier is run The humidifier is in operation.
Motion Sensor ON Indicates capacity savings by motion sensor control during operation or stop.
Radiant Sensor
In order to efficiently heat the room when the radiant temperature is low, the air
flow direction and air volume are automatically controlled.
Cold draft restrained In order to prevent indoor temperature from being too low.
Noise reduction The operation noise reduction control of the outdoor unit is set.
FrostWash is complete Indicates the FrostWash cycle has been run and completed.
IU temp. over range
FrostWash stopped
The FrostWash cycle has been aborted as the indoor temperature is out of the
allowable range 15°C to 30°C.
OU temp. over range
FrostWash stopped
The FrostWash cycle has been aborted as the outdoor temperature is out of the
allowable range of 1°C to 43°C.