No. Item Optional function
Individual
Setting
Settings Setting conditions Description
93
g
Not used -
00
- Use at 00 conditions
01
94
A
Not used -
00
- Use at 00 conditions
01
95
L1
Not used ○
00
- Use at 00 conditions
01
02
03
96
L2
Not used -
00
- Use at 00 conditions
01
02
03
97
L3
Operation of the louvres in
energy-saving thermo OFF
(Cooling / Dry mode)
○
00 Direct air blow Low (factory setting)
Power save must be ON in order
to use this function (L5 must be
set to 01).
This function is used to establish
louvre swinging operation ranging
from continuous swing to static
operation.
Low: Continuous louvre swing
Medium: Louvre swing with
intermittent stops for 20/40
seconds
High: Louvre stopped at full
opening position, according to the
setting of CF.
01 Direct air blow Medium
02 Direct air blow High
03 Disabled
98
L4
Fan acceleration in energy-
saving thermo OFF (Cooling
mode)
○
00
Function disabled
(factory setting)
This function increases fan speed
by one step to prevent the loss of
comfort due to the forced thermo
OFF for energy saving during
cooling operation.
01 Function enabled
99
L5
Louvre swing operation
during energy-saving forced
thermo OFF
○
00
Function disabled
(factory setting)
This function is used to enabled
the setting of function L3.
01 Function enabled
100
L6
Not used -
00
- Use at 00 conditions
01
101
L7
Not available -
“- -”
permanent
– –
102
L8
Not used -
00
- Use at 00 conditions
01
103
Lg
Not used ○
00
- Use at 00 conditions
01
104
LA
Not used -
00
- Use at 00 conditions
01
105
Lb
Not used -
00
- Use at 00 conditions
01
OPTIONAL FUNCTION
PMML0497 rev.1 - 12/2020
19