EasyManua.ls Logo

Hitachi RAC-50WX8 - Description of Main Circuit Operation

Hitachi RAC-50WX8
168 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 94 –
Fig. 1-1
751
631
C131
C751
C621
751
F
FM Rotation No.
Feedback
Indoor Fan
PWM Output
NO
ND
A−P−
14
40
Power to operate indoor unit (DC35V) is generated at the power supply in outdoor unit and it is sent to indoor unit
through the connecting cord C and D.
Then, DC 12V (12V line) is generated using DC/DC converter from the voltage sent from outdoor unit, as the
control voltage of 12V is required to drive the suction deflector motor and others.
Furthermore, 5V (5V line), which is necessary to drive the microcomputer and to control the fan motor, is generated
using three-terminal regulator IC121.
1. Power circuit
MODEL RAS-50WX8, RAS-D18EX3
DESCRIPTION OF MAIN CIRCUIT OPERATION
0V
35V