– 43 –
Notes:
(1) The sleep operation starts when the sleep key is pressed.
(2) When the sleep key is set, the maximum compressor speed is limited, and the indoor fan is set to “sleep Lo”.
(3) The indoor fan speed does not change even when the fan speed mode is changed.
(4) When operation is stopped during sleep operation, the set temperature when stopped, as well as the time, continue
to be counted.
(5) If the set lime is changed during sleep operation, all data including set temperature, time, etc. is cleared and restarted.
(6) If sleep operation is canceled by the cancel key or sleep key, all data is cleared.
Cooling Sleep Operation
Compressor speed
Maximum speed
Indoor fan
Outdoor fan
Timer lamp
Operation lamp
Sleep key
Set to 7 hours
P1
Hi
See basic operation
Med
Lo (sleep)
Lo
10 mins