– 8 –
CAUTION
● Do not wash with hot water at more than 40°C. The lter may shrink.
● When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to the sun.
The lter may shrink.
● Do not operate the air conditioner with the lter removed. Dust may enter the air conditioner and cause
trouble.
WARNING
● Before cleaning, stop unit operation with the remote controller and turn off the circuit breaker.
CAUTION
● Do not expose the unit to water as it may cause an electric shock.
● For cleaning inside the air conditioner, consult your sales agent.
● Avoid using detergent when cleaning the heat exchanger of the indoor unit. Unit failure may result.
● When cleaning the heat exchanger with a vacuum cleaner, make sure to wear gloves so as not to injure your
hands on the heat exchanger ns.
MAINTENANCE
1. AIR FILTER
PROCEDURE
Clean the air lter, as it removes dust inside the room. Be sure to clean the lter
once every two weeks so as not to consume electricity unnecessarily.
1
Loose the screw and release the lter holders. Pull the lter toward
center to take it out from indoor unit (refer to diagram).
2
Remove dust from the lter using a vacuum cleaner. If there is too
much dust, use neutral detergent. After using neutral detergent, wash
with clean water and dry in the shade.
3
Install the lters.
Slightly lift the suction grille and close as original state.
Filter
Screws
Filter
Indoor unit
Holders