EasyManua.ls Logo

Hitachi RAK-35RPC - Page 40

Hitachi RAK-35RPC
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
OPTION LIST
38
Example of wiring connection to Card Key Unit will be as below (reference only)
CARD KEY UNIT (Prepared by INSTALLER) AIR CONDITIONER INDOOR PCB
x CONNECTION EXAMPLE
i. Pin No. 3 of DIP SWITCH is set to OFF position (HI Input Active) for Dry Contact Type a
ii. Pin No. 3 of DIP SWITCH is set to ON position (LO Input Active) for Dry Contact Type b
Please refer to the actual manual supplied with the optional connecting cords SPX-WDC3 for more details.
AC
POWER
SUPPLY
䐟㻌Connecting Cord to PCB:
SPX-WDC3
䐠㻌Contact with sleeve
CN6
DIP SW (DSW1)
Dry contact
Card sensor
indicator
Window
Close: ON
Open: OFF
Window
Close: ON
Open: OFF
Card key unit
Insert Card: ON
Remove Card: OFF
Indoor unit
PWB
Connection
Connection
SERIAL CONNECTION
All SW O
ON
O
OPERATION
Connecting cord to PCB
Accessory# SPX-WDC3
Window
Close: OFF
Open: ON
Window
Close: OFF
Open: ON
Card key unit
Insert Card: OFF
Remove Card: ON
Indoor uni
t
PWB
Connection
Connection
PARALLEL CONNECTION
All SW O
OFF
O
OPERATION
Connecting cord to PCB
A
ccessory# SPX-WDC3

Other manuals for Hitachi RAK-35RPC

Related product manuals