WORKING RANGE
20
5 WORKING RANGE
5.1. POWER SUPPLY
Working Voltage
207V ~ 253V
Voltage Imbalance
Within a 3% Deviation from Each Voltage at the Main Terminal of
Outdoor Unit
Starting Voltage
Higher than 85% of the Rated Voltage
5.2. WORKING RANGE
Applicable models:
The temperature range is indicated in the following table.
Cooling
Heating
working range min (
o
max (C)
o
rated (C)
o
C) working range min (
o
max (C)
o
rated (C)
o
outdoor
C)
-10 43 35 outdoor -15 21 7
indoor 16 43 27 indoor 16 26 20
-30
-20
-10
0
10
20
30
40
50
5 10 15 20 25 30 35 40 45 50
Cooling working range
-30
-20
-10
0
10
20
30
40
0 5 10 15 20 25 30 35 40
Heating working range
Indoor Temperature
Indoor Temperature
Ambient Temperature
COOLING
HEATING
Ambient Temperature
RAC-35WPD
RAC-42WPD
RAC-18WPD
RAC-25WPD
RAC-50WPD