Hitachi RAS-18FH6 - MAIN PARTS COMPONENT; THERMOSTAT; FAN MOTOR; MAIN ELECTRIC COMPONENTS FOR OUTDOOR UNIT

Hitachi RAS-18FH6
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 17 –
MAIN PARTS COMPONENT
THERMOSTAT
Thermostat Specifications
FAN MOTOR
MAIN ELECTRIC COMPONENTS FOR OUTDOOR UNIT
Fan Motor Specifications
CONNECTION
TEMPERATURE
°C (°F)
INDICATION
16
INDICATION
24
INDICATION
32
MODEL RAS-18FH6, RAS-25FH6
THERMOSTAT MODEL IC
OPERATION MODE COOL HEAT
ON 16.7 (62.1) 18.7 (65.7)
OFF 16.0 (60.8) 19.3 (66.7)
ON 24.7 (76.5) 26.7 (80.1)
OFF 24.0 (75.2) 27.3 (81.1)
ON 32.7 (90.9) 34.7 (94.5)
OFF 32.0 (89.6) 35.3 (95.5)
M
RED
BLK
WHT
YEL
BLU
35V
5V
0V
0 - 5V
FG
MODEL
NAME RATING APPLICABLE MODELS
REVERSING VALVE COIL 135 (20 ˚C) RAC-18YH6, 25YH6
REACTOR L1 13 (mH), 0.224 RAC-18YH6, 25YH6
REACTOR L2 25.5 (mH), 0.37 RAC-18YH6, 25YH6
FILM CAPACITOR 45 (µF) RAC-18YH6, 25YH6
RAS-18FH6, RAS-25FH6
POWER SOURCE DC 5V, 35V
DC 140
- 350
V
OUTPUT 25W
40W
(Control circuit built in)
BLU : BLUE YEL : YELLOW BRN : BROWN WHT : WHITE
GRY : GRAY ORN : ORANGE GRN : GREEN RED : RED
BLK : BLACK PNK : PINK VIO : VIOLET
RED
140-
350V
BLK
0V
WHT
15V
M
YEL
0-6V
BLU
0-15V
RAC-18YH6, RAC-25YH6
RAS_AW_015-018e 2008.1.28, 16:0317