INSTALLATION AND OPERATION MANUAL
YUTAKI S/S80 Series
RAS-(3-6)H(V)RNME-AF
Outdoor Unit
PMML0205A rev.4 - 11/2012 Printed in Spain
PMML0205A rev.4 - 11/2012
YUTAKI S/S80 SERIES - OUTDOOR UNIT

Other manuals for Hitachi RAS-4HRNME-AF

Questions and Answers:

Hitachi RAS-4HRNME-AF Specifications

General IconGeneral
BrandHitachi
ModelRAS-4HRNME-AF
CategoryAir Conditioner
LanguageEnglish

Summary

PART I - OPERATION

IMPORTANT NOTICE

Key notices regarding compatibility, specifications, and manual usage.

SYSTEM DESCRIPTION

Explains the heat pump's function, energy efficiency, and features.

BEFORE OPERATION

Outlines power supply requirements, shutdown procedures, and handling of snow/ice.

AUTOMATIC CONTROLS

Explains functions like 3-minute guard, frost prevention, auto-restart, and defrost cycles.

BASIC TROUBLESHOOTING

Guides users on identifying and resolving common operational faults and abnormal sounds.

NAME OF PARTS

Outdoor Unit Components

Lists and illustrates the various components of the outdoor unit.

REFRIGERANT CYCLE

Refrigerant System Diagram

Shows the flow of refrigerant for cooling and heating, with component identification.

UNITS INSTALLATION

Outdoor Unit Installation Guidelines

Covers transport, placement, ventilation, and protection from environmental factors.

Installation Space Requirements

Details required clearances for single and multiple outdoor unit installations.

Installation Place Provision

Specifies requirements for concrete foundations, anchor bolts, and drainage.

REFRIGERANT PIPING & REFRIGERANT CHARGE

Piping Materials and Preparation

Specifies copper pipe requirements, cleaning, and insulation for piping.

Refrigerant Piping Suspension and Connection

Details how to suspend piping and connect it to outdoor units, including pipe routing.

Refrigerant Piping Design and Sizing

Covers design charts for piping length, height difference, and pipe size selection.

Refrigerant Charge and Vacuum Procedure

Outlines the process for charging refrigerant, performing vacuum tests, and pump-down.

DRAIN PIPING

Drain Discharging Boss and Connection

Explains the use and connection of the drain boss for water discharge.

ELECTRICAL WIRING

General Electrical Checks

Covers checks for electrical data compliance, voltage, impedance, and grounding.

Outdoor Unit Wiring Connections

Details wiring connections for outdoor units and the function of DIP switches.

Common Wiring Practices

Provides guidelines for wiring between indoor/outdoor units and compliance with local codes.

Wire Size Selection

Specifies recommended minimum wire sizes for power, transmitting, and actuator cables.

TEST RUN

Preliminary Checks Before Test Run

Covers checks for unit appearance, installation, electrical connections, and refrigerant circuit.

Test Run Procedure (Indoor Unit)

Guides users through executing and monitoring the test run using the remote control.

Test Run Procedure (Outdoor Unit)

Details test run setup via outdoor unit DIP switches for various operational modes.

SAFETY SUMMARY & CONTROL DEVICE SETTING

Compressor and Fan Motor Protection

Explains protection settings for compressor high pressure and fan motor temperature.

TROUBLESHOOTING

Alarm Code Indications

Provides a table of alarm codes, origins, details of abnormalities, and main factors.