– 5 –
above 50mm
above 100mm
above
0.45m
above 300mm
must not bend
above 100mm
2,300mm or more
Maximum pipe length 30m
Minimum pipe length 5m
above 200mm
above 700mm
above 200mm
above 50mm when
installed on the
ceiling of balcony
(
)
above 100mm
above 100mm
give clearance as
wide as possible
Plug
The difference in height
between the indoor and
outdoor unit should be kept
max 10m.
The connecting pipe, no
matter big or small, should
all be insulated with
insulation pipe and then
wrapped with vinyl tape. (The
insulator will deteriorate if it
is not wrapped with tape).
The connection of insulated
drain hose.
Please use insulated drain
hose for the indoor piping
(commercial product).
The indoor piping should be
insulated with the enclosed
insulation pipe. (If the insulator
is insufficient, please use
commersial products).
Be sure to
completely seal
any gap with putty.
CAUTION
The installation height of indoor unit must be 2.3m or more.
!
Figure showing the installation of Indoor and Outdoor unit