3.2.2.7 ERP additional data - YUTAKI S80
RAS-(4-6)WHVNPE + RWH-(4.0-6.0)VNF(W)E
Model
Outdoor unit RAS-4WH(V)NPE RAS-5WH(V)NPE RAS-6WH(V)NPE
Indoor unit RWH-4.0VNF(W)E RWH-5.0VNF(W)E RWH-6.0VNF(W)E
Electrical power input in stand-by mode (Psb) W 17.0 17.0 17.0
Electrical power input in thermostat-OFF mode (Pto) W 0.0 0.0 0.0
Electrical power input in OFF mode (Poff) W 17.0 17.0 17.0
Electrical power input in crankcase heater mode (Pck) W 0.0 0.0 0.0
Sound power level of indoor unit (L
WA
) dB(A) 57 57 58
Sound power level of outdoor unit (L
WA
) dB(A) 61 63 64
Capacity control mode - Variable (Inverter)
Integrated supplementary heater kW No
Nominal outdoor air ow m
3
/h 4800 5400 6000
RAS-(4-6)WHNPE + RWH-(4.0-6.0)NF(W)E
Model
Outdoor unit RAS-4WHNPE RAS-5WHNPE RAS-6WHNPE
Indoor unit RWH-4.0NF(W)E RWH-5.0NF(W)E RWH-6.0NF(W)E
Electrical power input in stand-by mode (Psb) W 44.0 44.0 44.0
Electrical power input in thermostat-OFF mode (Pto) W 0.0 0.0 0.0
Electrical power input in OFF mode (Poff) W 44.0 44.0 44.0
Electrical power input in crankcase heater mode (Pck) W 0.0 0.0 0.0
Sound power level of indoor unit (L
WA
) dB(A) 57 57 58
Sound power level of outdoor unit (L
WA
) dB(A) 61 63 64
Capacity control mode - Variable (Inverter)
Integrated supplementary heater kW No
Nominal outdoor air ow m
3
/h 4800 5400 6000
3.2.2.8 ERP additional data - YUTAKI M
RASM-(3-6)VNE
Model
RASM-3VNE RASM-4VNE RASM-5VNE RASM-6VNE
Electrical power input in stand-by mode (Psb) W 15.0 13.1 13.1 13.1
Electrical power input in thermostat-OFF mode (Pto) W 0.0 0.0 0.0 0.0
Electrical power input in OFF mode (Poff) W 15.0 13.1 13.1 13.1
Electrical power input in crankcase heater mode (Pck) W 0.0 0.0 0.0 0.0
Sound power level of outdoor unit (L
WA
) dB(A) 64 64 65 67
Capacity control mode - Variable (Inverter)
Integrated supplementary heater kW No
Nominal outdoor air ow m
3
/h 2682 4800 5400 6000
RASM-(4-6)NE
Model
RASM-4NE RASM-5NE RASM-6NE
Electrical power input in stand-by mode (Psb) W 19.1 19.1 19.1
Electrical power input in thermostat-OFF mode (Pto) W 0.0 0.0 0.0
Electrical power input in OFF mode (Poff) W 19.1 19.1 19.1
Electrical power input in crankcase heater mode (Pck) W 0.0 0.0 0.0
Sound power level of outdoor unit (L
WA
) dB(A) 64 65 67
Capacity control mode - Variable (Inverter)
Integrated supplementary heater kW No
Nominal outdoor air ow m
3
/h 4800 5400 6000
GENERAL DATA
PMML0335A rev.1 - 04/2016
32