3.5.4 Monobloc system - YUTAKI M
RASM-(3-6)(V)NE
Model Power supply
Applicable voltage
Operation mode
Compressor and fan motors
MC
(A)
Max.
IPT
(kW)
U max.
(V)
U min.
(V)
PH
STC
(A)
RNC
(A)
IPT
(KW)
RASM-3VNE
1~ 230V 50Hz 253 207
Without DHW tank heater
1~
-
8.5 1.93 18.0 4.09
With DHW tank heater 21.5 4.93 33.0 7.56
RASM-4VNE
Without DHW tank heater 9.2 2.10 30.8 7.01
With DHW tank heater 22.3 5.10 45.8 10.47
RASM-5VNE
Without DHW tank heater 13.1 2.98 30.8 7.01
With DHW tank heater 26.2 5.98 45.8 10.47
RASM-6VNE
Without DHW tank heater 16.2 3.69 30.8 7.01
With DHW tank heater 29.3 6.69 45.8 10.47
RASM-4NE
3N~ 400V 50Hz 440 360
Without DHW tank heater
3N~
3.4 2.10 14.3 8.77
With DHW tank heater 12.2 5.10 29.3 12.24
RASM-5NE
Without DHW tank heater 4.9 2.98 14.3 8.77
With DHW tank heater 14.3 5.98 29.3 12.24
RASM-6NE
Without DHW tank heater 7.2 2.98 24.3 10.02
With DHW tank heater 17.5 5.98 39.4 13.49
? NOTE
The data corresponding to DHW tank heater is calculated in combination with the domestic hot water tank accessory “DHWT-(200/300)S-3.0H2E”.