DHW tank installed beside the indoor unit - RWH-(4.0-6.0)(V)NFWE + DHWS(200/260)S-2.7H2E
Units in mm.
Mark Part name Remarks
1 Flexible water pipe (x4)
For heating coil inlet and outlet connections of indoor unit
and DHW tank
2 Extension cables For tank electric heater
3 Extension cables For tank thermistor
4 Extension cables For unit controller
5 Gasket (x5) *DVNHWV[IRUHDFKÀH[LEOHZDWHUSLSHHQGIRUVSDUH
Top view
Left side
Front view
Right side
>500mm (Min. distance
for E-box removal)
(*2) Minimum distance for
piping connection back outlet
Dimensions according to the unit (mm)
Unit Dimension "a"
RWH + DHWS200S-2.7H2E 1980
RWH + DHWS260S-2.7H2E 2289
(*1) Recommended distance
between indoor unit and tank
may vary from 0 to 200 mm
Option 1
Option 2
Indoor unit at the
left side of tank
Indoor unit at the right
side of tank
Indoor unit
Tank
Service with this space is possible
but, for an easier servicing of some
components it is recommended to
let a space >500mm
GENERAL DIMENSIONS
PMML0340B rev.1 - 03/20166