EasyManua.ls Logo

HiWeigh KPC - Calibration

Default Icon
15 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
7
Press
Press1
Press1
10
AutP
10
1
11
Ones place digit (the 0 of 10) represents the option of
automatically power off function or not.
Ones place0:No automatic power off function
Ones place1:Automatic power off
Tens place digits (the 1 of 10) represents zero tracking
range (1~9):
1:0.4 d 2:0.8 d 3:1.2 d 4:1.6 d
5:2 d 6:2.4 d 7:2.8 d 8:3.2d 9:3.6 d
Also Tens place represents the zero range upon power
on:
Tens digit0 not zero when power on
Tens digit>0 zero rang is 20F·S when power on
EgAutP11
8
Press
01
-Adr-
01
Communication address choseserial continuous
output format
Adr = 00 (weight sending from end, 100.0 = 0.001)
Adr=99 (weight sending from beginning, 100.0 =100.0)
Adr=98 (Amount/Quantity)
Adr=01-97 (serial printing ouput)
9
Press
Press
2400
bAud
2400
4800
Baud Rate chose240048009600
Eg: b=4800
10
Press
0
P-c
0
Mode chose when power on
0--Price computing
1--Counting
Eg: 0
11
Press
2
P-Pt
2
Decimal point (in total amount window) chose0-4
0---none
1-4----0.0 0.00 0.000 0.0000
Eg: 2
12
Press
0
End of parameter setting
V. Calibration
After parameter setting, you can start to do calibration according to following steps:
Step
Operation
Display
Note
1
Press
------
SEt
------
Needs password, input 8888 and press
Enter calibration mode