EasyManua.ls Logo

Hokkaido V-Design Series User Manual

Hokkaido V-Design Series
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
R32
Refrigerant
Air Conditioners
Heat Pump “WallType DC Inverter Models
1 Phase, 220-240V, 50Hz Power Supply
V-Design Series:
HKEU (262, 352) ZAL-B
HCNI (262, 352) ZA
Service Manual
[
Release 1.0
]
(optional)

Questions and Answers:

Hokkaido V-Design Series Specifications

General IconGeneral
Power Supply220-240V, 50Hz
RefrigerantR32
SEER22
Noise Level (Outdoor)50 dB
FeaturesSleep Mode

Summary

Safety Precautions

In case of Accidents or Emergency

Procedures to follow in case of gas leaks, unusual sounds, smoke, or contact with liquid.

Pre-Installation and Installation

Guidelines for safe installation, including electrical circuit requirements and qualified personnel.

Operation and Maintenance

Precautions during operation and maintenance, including grounding, flammable materials, and cleaning.

Specifications

Product Overview

Highlights key features like Turbo function, High density filter, Light effects, and Louver position.

Technical Data Tables

Detailed performance and electrical specifications for different models, including operating ranges and efficiency.

Pipe Length and Drop Height

Information on maximum pipe length, elevation limits, and additional refrigerant requirements.

Electrical Wiring Diagrams

Schematic diagrams for indoor unit wiring, showing connections and components.

Product Features

Display Function

Explains unit display functions, including temperature, timer, and mode indicators.

Safety Features

Details safety mechanisms like compressor delay, shut-off functions, and refrigerant leakage detection.

Basic Functions

Describes core operational modes like Cooling, Heating, and Auto mode with fan control.

Optional Functions

Covers features such as 8°C Heating, Self Clean, Follow Me, and SILENCE mode.

Maintenance

First Time Installation Check

Ensures no air or moisture is trapped in the system and performs a leak test.

Refrigerant Recharge

Procedure for adding refrigerant if piping length exceeds the chargeless length.

Re-installation

Steps for collecting refrigerant into the outdoor unit prior to re-installation.

Outdoor Units Disassembly

Outdoor Units Dimensions

Provides detailed measurements and diagrams for the outdoor unit models.

Disassembling the Outdoor Unit

Step-by-step instructions for removing panels, covers, and electrical parts.

Troubleshooting

General Troubleshooting

Details error codes displayed on the unit and their corresponding error information.

Troubleshooting by Error Code

Provides specific diagnosis and solutions for common error codes like E0, F4, E1, E2, etc.

Check Procedures

Guides on checking components like temperature sensors and compressor resistance.

Appendix

Temperature Sensor Resistance Value Tables

Lists resistance values for temperature sensors (T1, T2, T3, T4) at various temperatures.

Pressure on Service Port (R32 Refrigerant)

Provides charts and graphs showing pressure values for cooling and heating modes.

Related product manuals