e-ICE User’s Guide
9
e-ICE Operating Notes
HT-IDE3000 Version
Make sure the IDE3000 in use is the latest version before using the e-ICE.
Check the e-ICE version from “Help\About HT-IDE3000…” in the IDE3000 function list.
If the version is V7.4 or above, when the IDE3000 is activated, the IDE will auto-detect
the version info and suggest if it is necessary to upgrade, or click “Help\Check Live
Update…” for a manual upgrade.
Figure 12 About HT-IDE3000
Figure 13 Help
System Frequency
For simulation convenience, check the red box as shown in the figure below to select
an MEV board supplied DEV operating frequency source. During e-ICE simulation an
externally connected HXT, ERC or LXT oscillator is not permitted. However, the
required oscillator should be connected for actual IC applications.
Figure 14 SysFreq Frequency Setup Window