4.2 Choose your location
⚫ If tipped more than 45°, allow the
unit to set upright for at least 24
hours before start up.
⚫ Place the unit on a firm, level surface
in an area with at least 50cm of free
space around it to allow for proper air
circulation.
⚫ Do not operate in close proximity to
walls, curtains, or other objects that
may block air inlet and outlet. Keep
the air inlet and outlet free of obstacles.
⚫ Never install the unit where it could be subject to:
➢ Heat sources such as radiators, heat registers, stoves or other
products that products that produce heat.
➢ Direct sunlight
➢ Mechanical vibration or shock
➢ Excessive dust
➢ Lack of ventilation, such as cabinet or bookcase
➢ Uneven surface
WARNING!
Install the unit in rooms which exceed 7 m² for 5000-
7000BTU/h model,8m² for 8000BTU/h model,9m² for
9000BTU/h model,10m² for 10000BTU/h model.
Do not install the unit in a place where inflammable gas
may leak.
NOTE!
The manufacture may provide other suitable example or
may provide additional information about the refrigerant
odour.