Page 14
CAUTION:
On a level surface with the engine off, check the oil level
before each use of the generator.
STARTING THE ENGINE
See Figures 5 - 7.
NOTE: If location of generator is not level, the unit may not
start or may shut down during operation.
Unplug all loads from the generator.
Switch the AC circuit breaker to the OFF position.
Turn the fuel valve to the ON position.
Move the choke lever to the START position.
NOTE: If engine is warm or the temperature is above
50˚F, move the choke lever in the RUN position.
Put the engine switch in the ON ( l ) position.
Pull the recoil starter grip until the engine runs (a maximum
of 6 times).
NOTE: Do not allow the grip to snap back after starting;
return it gently to its original place.
Allow the engine to run for 30 seconds, then move the
choke lever to the RUN position.
Switch the AC circuit breaker to the ON position.
STOPPING THE ENGINE
See Figures 5 - 6.
To stop the engine under normal operating conditions:
Remove any load from the generator.
Switch the AC circuit breaker to the OFF position.
Turn the fuel valve to the OFF position.
Put the engine switch in the OFF (O) position.
To stop the engine in an emergency situation:
Put the engine switch in the OFF (O) position.
OPERATION
Fig. 7
Fig. 5
Fig. 6
FUEL VALVE
POSITIONS
OFF
ON
CHOKE
LEVER
TO START (CHOKE CLOSED)
ENGINE
SWITCH
RECOIL
STARTER GRIP
CIRCUIT
BREAKER
TO RUN (CHOKE OPEN)