TROUBLESHOOTING
IF THESE SOLUTIONS DO NOT SOLVE THE PROBLEM CONTACT YOUR AUTHORIZED SERVICING DEALER.
PROBLEM POSSIBLE CAUSE SOLUTION
Engine will not start. 1. No spark.
2. No fuel.
3. Starter rope pulls harder now
than when new.
1. Check spark. Remove spark plug. Reattach the spark plug
cap and lay spark plug on metal cylinder. Pull the starter
rope and watch for spark at spark plug tip. If there is no
spark, repeat test with a new spark plug.
2. Push primer bulb until fuel is visible in the bulb. If fuel is
not apparent, the primary fuel delivery system is blocked.
Contact a servicing dealer. If primer bulb fills, engine may
be flooded (see next item).
3. Contact a servicing dealer.
Engine starts but will
not accelerate.
Carburetor requires adjustment. Contact a servicing dealer.
Engine starts but will
only run at high speed
at half choke.
Carburetor requires adjustment. Contact a servicing dealer.
Engine does not reach
full speed and emits
excessive smoke.
1. Oil / fuel mixture is incorrect.
2. Air filter is dirty.
3. Carburetor requires
adjustment.
4. Spark arrestor screen is dirty.
1. Use fresh fuel and the correct 2-cycle oil mix.
2. Clean air filter, refer to “Replacing and Cleaning the Air
Filter” earlier in this manual.
3. Contact a servicing dealer.
4. Contact a servicing dealer.
Engine starts, runs,
and accelerates, but
will not idle.
Carburetor requires adjustment. Turn idle speed adjustment screw clockwise to increase idle
speed. See Figure 15.
IDLE SPEED
ADJUSTMENT
SCREW
Fig. 15

Other manuals for Homelite VAC ATTACK II UT08042

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Homelite VAC ATTACK II UT08042 and is the answer not in the manual?

Homelite VAC ATTACK II UT08042 Specifications

General IconGeneral
BrandHomelite
ModelVAC ATTACK II UT08042
CategoryBlower
LanguageEnglish

Related product manuals