TAKING CARE OF UNEXPECTED PROBLEMS
69
ENGINE AUTOMATICALLY STOP AND THE CO ALARM INDICATOR FLASHING
ENGINE AUTOMATICALLY STOP AND THE FAULT/CO SENSOR LIFE
INDICATOR FLASHING
FAULT/CO SENSOR LIFE INDICATOR FLASHING WHEN RUNNING THE
ENGINE
Possible Cause Correction
CO concentration around the
generator is high.
Review the location of the generator,
and place it in a well-ventilated
outdoor location (see page 22).
When the engine is stopped
automatically by CO-MINDER®, press
the CO-MINDER® reset button to
restart the engine (see page 41).
Possible Cause Correction
CO sensor malfunction. If the engine cannot be started and the
CO ALARM indicator flashes, even if the
location of the generator has changed,
there may be a CO-MINDER®
malfunction. Consult an authorized
Honda Power Equipment dealer.
CO sensor may have reached the end
of its useful lifespan (see page 23).
Consult an authorized Honda Power
Equipment dealer.
Possible Cause Correction
CO sensor may reach the end of its
useful lifespan (see page 23).
Consult an authorized Honda Power
Equipment dealer for replacement.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU3200i and is the answer not in the manual?

Honda EU3200i Specifications

General IconGeneral
ModelEU3200i
CategoryPortable Generator
Run Time per Tankful at 1/4 Load8.6 hours
Dry Weight59.1 lbs
Dimensions22.5" x 12.0" x 17.8"
Starting Watts3200W
Running Watts2600W
InverterYes
Run Time at 1/4 Load8.6 hours
Starting SystemRecoil
Maximum AC Output3200W
Rated AC Output2600W
Engine Type4-stroke
DC Output12V, 8A
Fuel Tank Capacity1.2 gallons
Outlets1x 120V 20A (5-20R), 1x 120V 30A (TT-30R)