85
ASSEMBLY
Engine Oil
The generator is shipped
WITHOUT OIL in the engine.
Place the generator on a level
surface. Open the right
maintenance cover by turning
its latch counterclockwise.
Remove the oil filler cap.
Add enough of the
recommended oil to bring the
oil level to the upper limit of
the oil filler neck.
Use a 4-stroke motor oil that
meets the requirements for
API service category SE or
later (or equivalent).
SAE 10W-30 is recommended
for general, all-temperature
use. Other viscosities in the
chart may be used when the
temperature in your area is
within the indicated range.
Reinstall the oil filler cap
securely.
Close the right maintenance
cover by turning its latch
clockwise.
Fuel
Refer to page 52.
AMBIENT TEMPERATURE
OIL FILLER CAP
OIL FILLER NECK
UPPER
LIMIT
36Z376000.book 85 ージ 014年9月19日 金曜日 午後6時26分

Table of Contents

Other manuals for Honda EU70is

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU70is and is the answer not in the manual?

Honda EU70is Specifications

General IconGeneral
ModelEU70is
TypeInverter
Maximum AC Output7000 VA
Rated AC Output5500 VA
EngineGX390
Engine Displacement389 cc
Fuel TypeGasoline
Run Time per Tankful6.5 hours at rated load
Starter SystemElectric
DC Output12V, 8.3A
Run Time at 1/4 Load18 hours
Noise Level52 dB(A) at 1/4 load
Rated Voltage220-240V