VISTA-15P/20P/SIA Installation and Setup Guide
14
System Communication and Operation (Continued)
The following table lists codes for reports sent in different formats:
Code for Code for
Type of 3+1/4+1 3+1/4+1 Code for
Report Standard Expanded 4+2
Alarm SSS(S) A SSS(S) A SSSS AZ
AAA(A) Z
Trouble SSS(S) T SSS(S) T SSSS Tt
TTT(T) t
Bypass SSS(S) B SSS(S) B SSSS Bb
BBB(B) b
AC Loss SSS(S) E SSS(S) E SSSS EA
C
EEE(E) A
C
Low Batt SSS(S) L SSS(S) L SSSS LL
B
LLL(L) L
B
Open SSS(S) O SSS(S) O SSSS OU
OOO(O) U
Close SSS(S) C SSS(S) C SSSS CU
CCC(C) U
Test SSS(S) G SSS(S) G SSSS Gg
GGG(G)g
Restore SSS(S) R SSS(S) R SSSS RZ
Alarm RRR(R) Z
AC Restore SSS(S) R
A
SSS(S) R
A
SSSSR
A
A
c
R
A
R
A
R
A
(R
A
)A
c
LoBat Res. SSS(S) R
L
SSS(S) R
L
SSSS R
L
L
B
R
L
R
L
R
L
(R
L
)L
B
Trouble Res. SSS(S) R
T
SSS(S) R
T
SSSS R
T
t
R
T
R
T
R
T
(R
T
)t
Bypass Res. SSS(S) R
B
SSS(S) R
B
SSSS R
B
b
R
B
R
B
R
B
(R
B
)b
Where:
SSS or SSSS = Subscriber ID C = Close Code1st Digit
A = Alarm Code1st digit U = User Number (in hex)
Z = Typically Zone Number*2nd digit Gg = Test Code (1st & 2nd digits)
Tt = Trouble Code (1st & 2nd digits) R = Restore Code (Alarm)
Bb = Bypass Code (1st & 2nd digits) R
T
t = Restore Code (Trbl) 1st & 2nd digits
EA
C =
AC Loss Code (1st & 2nd digits) R
B
b = Restore Code (Byps) 1st & 2nd digits
LL
B =
Low Battery Code (1st & 2nd digits) R
A
A
C
=
Restore Code (AC) 1st & 2nd digits
O = Open Code1st Digit R
L
L
B =
Restore Code (Bat) 1st & 2nd digits
*Zone numbers for: & #, or B = 99; 1 + , or A = 95; 3 + #, or C = 96; Duress = 92

Table of Contents