BENDIX/KING KX 165A
Rev 0, Jun/2000 15610M00.RCD Page 5-25
5. Memory: ____________ OK
When the unit is turned OFF and then back ON that the last active and stand-
by frequencies entered are displayed.
6. 25 kHz Switch: ____________ OK (pull out Comm Inc/Dec inner knob)
**5.a 8.33 kHz Switch: ___________ OK (pull out Comm Inc/Dec inner knob)
7. Mode Switch
With normal active and standby frequency displayed, press mode button once.
CDI readout _______ OK (Flag indication will be present if no signal is present)
Press mode button
TO (bearing readout) ______ OK (TO and 3 horizontal bars displayed if no sig-
nal is present)
Press mode button
FROM (radial readout) ______ OK ("FR" and 3 horizontal bars displayed if no
signal is present)
Press mode button
Elapsed timer readout ______ OK
8. Channel button
Press channel button
Channel # ______ OK (Channel # disappears after 5 seconds)
9. Unit Current
In receive mode: ______ NMT 0.6 A at 27.5 VDC
In transmit mode: ______ NMT 4.0 A at 27.5 VDC