BENDIX/KING KX 165A
Rev 0, Jun/2000 15610M00.RCD Page 5-49
POINT VDC TEST CONDITIONS SHT DESCRIPTION
"R267,R264" 8.4 No input signal applied 4 VCO power
Q34 source 2.2 No input signal applied 4 2nd IF Amp
U23 pin 17 8.7 No input signal applied 4 AM Receiver IC power
U23 pin 1 9.2 No input signal applied 4 AM Receiver IC Mixer pow-
er
TP7 1.12 No input signal applied 4 IF AGC
TP7 1.6 Standard Nav Input 4 IF AGC
TP7 1.7 Standard Nav Input,
except -30 dBm signal
4IF AGC
P3001 pin 29 -5 to -9 No input signal applied 4 RF AGC
P3001 pin 29 >0.8 Standard Nav Input,
except -30 dBm signal
4RF AGC
Notes: Standard Comm Input: -76dBm, 127.00MHz, 1000Hz/30% modulated tone
Standard Nav Input: -76dBm, 113MHz, 1000Hz/30% modulated tone
When only single component is listed, reading is taken on non-ground side of component
All voltages are referenced to chassis ground.