INSTALLATION MANUAL
89000007
Page A-2
15 Nov 2013
© Honeywell International Inc. Do not copy without express permission of Honeywell.
Table A-1. Environmental Qualification Form (Cont)
Conditions
DO-160G
Section Description of Conducted Tests
Humidity 6.0 Equipment tested to Category A
Operational shocks 7.2 Equipment tested to Category B
Crash safety 7.3 Equipment tested to Category B
Vibration 8.0 Aircraft Zone 2; Type 3, 4, 5 to
Category S, Level M
Aircraft Zone 2; Type 1 (helicopters) to
Category U, Level G
Explosion 9.0 Equipment identified as Category X, no test
required
Waterproofness 10.0 Equipment identified as Category X, no test
required
Fluids susceptibility 11.0 Equipment identified as Category X, no test
required
Sand and dust 12.0 Equipment identified as Category X, no test
required
Fungus 13.0 Equipment identified as Category X, no test
required
Salt spray 14.0 Equipment identified as Category X, no test
required
Magnetic effect 15.0 Equipment tested to Category Z
Power input 16.0 Equipment tested to Category BX
Voltage spike 17.0 Equipment tested to Category B
Audio frequency
conducted susceptibility
18.0 Equipment tested to Category B
Induced signal
susceptibility
19.0 Equipment tested to Category AC