EasyManua.ls Logo

Honeywell BK-G4AT User Manual

Honeywell BK-G4AT
14 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
www.docuthek.com
D GB F NL I SK RUS E RORO
SRBSRB SRBCZ P
© 2018 Elster GmbH · Edition 01.18
Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
, , , ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Changes to edition 07.7
The following chapters have been changed:
Checking the usage
– Commissioning
– Accessories
Technical data
Declarations of conformity
ATEX legend
– Logistics
Contents
Operating instructions
D
GB
F
NL
I
SK
RUS
E
RO
SRB
GB-1
1000063767-002-20
Translation from the German
Safety
Contents
Diaphragm gas meters
BK-G.6 to BK-G5
Diaphragm gas meters
BK-G.6 to BK-G5 .....................
Contents ..............................
Safety.................................
Checking the usage .....................
Diaphragm gas meters BK-G1.6 to G25 ......2
BK with integrated “Smart Valve” ............2
Type code .............................2
Part designations ........................2
Type label/Index plate.....................2
ATEX identification .......................3
Installation ............................4
Temperature test point ..................5
Pressure test point on housing (optional) ...5
Connecting the piping ....................6
Pressure test point on outlet connector
(optional) ..............................6
Opening the test nipple ...................6
Closing the test nipple ....................6
Tightness test ..........................6
Commissioning.........................7
Maintenance/Removal...................8
Accessories ...........................8
Technical data .........................9
Declarations of conformity ..............0
ATEX legend ..........................14
Logistics .............................4
Contact ..............................4
03250886
Question and Answer IconNeed help?

Do you have a question about the Honeywell BK-G4AT and is the answer not in the manual?

Honeywell BK-G4AT Specifications

General IconGeneral
BrandHoneywell
ModelBK-G4AT
CategoryMeasuring Instruments
LanguageEnglish

Summary

Safety

Safety instructions

Information relevant for safety, indicated by DANGER, WARNING, and CAUTION symbols.

Operating instructions

Diaphragm gas meters BK-G1.6 to BK-G25

Operating instructions for diaphragm gas meters model BK-G1.6 to BK-G25.

Checking the usage

Diaphragm gas meters BK-G1.6 to G25

Details on residential and commercial diaphragm gas meters BK for recording gas consumption.

ATEX identification

BK-G..M, BK-G..C, BK-G..MT, BK-G..CT

ATEX identification for specific models, including category, atmosphere type, and group.

BK-G..M, BK-G..C, BK-G..MT, BK-G..CT with RFID passive tag

ATEX identification for models with RFID passive tag, including conditions and atmosphere.

BK-G..A, BK-G..AT

ATEX identification for BK-G..A and BK-G..AT models, detailing category, atmosphere, and electrical parameters.

Installation

General Installation Warnings

Critical warnings to ensure safe installation and prevent damage to persons or the gas meter.

Installation (continued)

Applicable Regulations and Potential Hazards

Notes on national regulations, explosive atmospheres, equipotential bonding, and protection from falling parts.

Mounting and Connection Practices

Instructions for vertical installation, flow direction, contact with masonry, seal face inspection, and seal centering for co-axial meters.

Connecting the piping

WARNING: Ensuring Gas Meter Tightness

Crucial warnings to ensure the gas meter is tight, covering pressure test nipple handling and material compatibility.

Pipework Installation and Material

Instructions for installing pipes using specific materials, ensuring they are free from mechanical stress.

Tightness test

Procedure for checking pipework leaks and gas meter tightness, including pressure application and consumer status.

Commissioning

Valve Operation and Safety

Responsibility for Remote Shut-down

Clarification of grid operator responsibility for safe remote shut-down and restart of diaphragm gas meters.

Valve Variant Vs (Smart Valve)

Warning regarding limited gas flow rate and assessment by grid operator for Smart Valve function.

Maintenance and Removal

WARNING: Gas Residue and Explosion Risk

Safety measures for gas residue in meters, including purging with inert gas and transport precautions.

Technical Data

Gas Meter Specifications

Details on gas types, operating pressure, measuring range, and temperature ranges for BK diaphragm gas meters.

BK Gas Meters with Explosion Protection

Limitations on ambient and gas temperatures for Category 1 meters and parameters for pulse transmitters.

BK Gas Meters with Integrated "Smart Valve" Vs

Suitability for gases, opening/closing times, minimum operating pressure, and leakage flow for Smart Valve.

ATEX Declaration

BK-G..M, BK-G..C, BK-G..MT, BK-G..CT with ATEX declaration

EU Declaration of Conformity for specific models with ATEX declaration, listing directives, standards, and tests.

ATEX Declaration with RFID

BK-G..M, BK-G..C, BK-G..MT, BK-G..CT with RFID passive tag and ATEX declaration

EU Declaration of Conformity for models with RFID and ATEX, including directives, standards, and test reports.

Declarations for BK-G..A, BK-G..AT

EU Declaration of Conformity for BK-G..A, BK-G..AT

EU Declaration of Conformity for BK-G..A and BK-G..AT meters, covering MID and EMC directives.

ATEX legend

Marking of Explosion Protection

Explanation of ATEX markings related to explosion protection, equipment groups, categories, and atmosphere types.

Explosion Group and Temperature Class

Definition of explosion groups (IIB, IIA) and temperature classes (T1, T4, T6) for gases.

Related product manuals