CW45 Mobile Computer User Guide 39
Multicode Scan When you enable Multicode Scan, each barcode is checked to
see whether it satisfies the defined multicode rules before the
results are transmitted. Options include:
Enable or disable multicode scanning.
Set the number of barcodes.
Specify a separator to be used between barcodes.
Define up to 10 barcodes to be included in the
multicode.
Set a timeout in milliseconds. If set with a non-zero
value, the timeout starts after the scan button is
pressed. Once the timeout occurs, scanning will return
to standard (single) barcode mode.
Enable or disable the transmission of an incomplete
multicode. When enabled, the incomplete multicode is
transmitted when the incomplete transmission
timeout expires.
Set a timeout in milliseconds to use when incomplete
transmission is enabled. If set with a non-zero value,
the timeout starts after the scan button is pressed.
Once the timeout occurs, the results that were
collected before the timeout happened will be
transmitted if they satisfy the defined multicode rules.
Disabled
Preferred
Symbology
Settings
Use this setting to establish which barcode has priority if more
than one barcode appears on the same label.
Tap the check box to toggle the feature On or Off.
•Select Preferred Symbology Settings to adjust the
feature parameters.
Options include:
Preferred Timeout (ms)
The length of time the scanner will ignore a low priority
barcode while it searches for a high priority barcode. If a
high priority symbology is located during this period, then
that data is read immediately. If the time-out period expires
before a high priority symbology is read, the scanner will
read any barcode in its view. The default is 500ms.
•Symbology
Set the priority level (High or Low) for symbology codes.
This is used when you want to specify one symbology as a
higher priority over other symbologies in situations where
both barcode symbologies appear on the same label, but
the lower priority symbology cannot be disabled. If a code
is set as a High Priority, the decode of that symbology is
accepted immediately. If a code is set as a Low Priority, the
decode is buffered to see if a decode of a preferred High
Priority symbology can be found within a given timeout
period.