Installation guide 762 VITO interfaces & VITO probes Page 1
Installation guide 762 VITO Interfaces
& VITO, MTT, LT, MRT and MPT probes
June 2014
Part no. 4416.648
Rev. 9
Honeywell Enraf
P.O. Box 812
2600 AV Delft
Netherlands
Tel.: +31 15 2701100
Fax: +31 15 2701111
E-mail: hfs-tac-support@honeywell.com
H
Website: www.honeywellenraf.com
Question and Answer IconNeed help?

Do you have a question about the Honeywell Enraf VITO 767 and is the answer not in the manual?

Honeywell Enraf VITO 767 Specifications

General IconGeneral
Power Supply24 V DC
MaterialStainless Steel
Housing materialAluminum or Stainless Steel
Process Temperature-40 to 85 °C
Process PressureUp to 40 bar
Signal Output4-20 mA HART
Protection RatingIP67
Communication ProtocolHART
Operating temperature-40 °C to +80 °C (-40 °F to +176 °F)
Ingress protectionIP67

Summary

Safety

Safety Aspects of VITO Interfaces and Probes

Discusses safety aspects, certifications, and environmental conditions for interfaces and probes.

Personal Safety

Details personal safety requirements for technicians in hazardous areas.

Safety Conventions

Explains the meaning and usage of warnings, cautions, and notes in the guide.

Mechanical Installation

Mechanical Installation of 764/767/361/MRT Temperature Probe

Covers the mechanical installation of specific temperature probes.

Static Electricity Danger During Installation

Warns about and instructs on preventing static electricity during probe installation.

Mechanical Installation of 765/766/768/365 Water and Temperature Probes

Covers mechanical installation for specific water and temperature probes.

VITO Interface Installation Procedure

Details the procedure for installing the VITO Interface.

Removing VITO Temperature Probe on Cryogenic Tank

Provides instructions for safely removing probes from cryogenic tanks.

Standard Version (without optional IP adapter) Installation

Covers installing the standard VITO Interface without an IP adapter.

Optional IP Adapter Installation

Details installing the VITO Interface with an optional IP adapter.

VITO Interface with Optional IP Adapter Assembly

Steps for assembling the VITO Interface with an optional IP adapter.

Electrical Installation

Power Off and Enclosure Closing Warning

Emphasizes powering off before opening and closing the cover.

Bonding of the VITO Interface

Details the requirement and procedure for proper bonding of the VITO Interface.

VITO Interface Wiring to Tank Level Gauge

Explains wiring connections between VITO Interface and tank level gauge.