Refer to Supplemental Information (next page) for complete descriptions of these installation steps
5-051-736-00A Page 1
Fl
e
x
Gua
r
d
®
F
G
-1
6
2
5/
F
G
-1
6
2
5
T
G
l
assb
r
ea
k D
e
t
ec
t
o
r In
s
t
a
ll
a
ti
o
n In
s
tr
uc
ti
o
n
s
FG-1625/FG-1625T Glassbreak Detector
1625_001-V1
Tamper Switch
Rear Tamper
(FG-1625T only)
Terminal Block
(FG-1625T only)
Wire Entry Hole
Mounting Hole
Mounting Hole
Microphone
LED Indicators
Test Mode Pads
Front Cover
Terminal Block
Cover Screw Location
Select Mounting Location
Wall Mount
(Top View)
1625_wall_mnt-V0
1625_ceiling_mnt-001-V0
Ceiling Mount: (Side View)
Test Location w/ 9V Battery
V+
V
9V
9V_001-V0
Set Sensitivity & LED Configuration
1625_004-v1
SENS1
SENS2
LATCH
LED
2341
ON
ON
1
2
3
4
SENS1 & SENS2 configure sensitivity
SENSITIVITY APPROXIMATE
RANGE
SENS1 SENS2
MAX 7.6m (25 ft)
OFF OFF
MEDIUM 4.6m (15 ft)
ON OFF
LOW 3m (10 ft)
OFF ON
LOWEST 1.5m (5 ft)
ON ON
NOTE: Ranges are approximate and vary with each room’s
acoustic properties. Always verify range with a FG-701
Glassbreak Simulator.
The LATCH and LED DIP switches configure LED
indicator behavior.
SWITCH OFF ON
LATCH
Red LED lights for 5
seconds during alarm
Red LED latches ON when
detector goes into alarm
1, 2
LED
LEDs disabled (except for
power up and test mode
3
)
LEDs always enabled
1
The timing of the alarm relay is not affected by the latched Alarm LED.
2
Reset the Alarm LED by removing/restoring power, or by toggling the
detector in and out of Test Mode.
3
LEDs can be enabled/disabled using FG-701.
Enable Wall Tamper (FG-1625T only)
Remove plastic tab from rear of detector.
Install wall tamper screw as shown.
Set screw depth to make contact w/ bottom of
tamper cavity when device is installed
1625_005-V0
Connect Detector
Connect detector using 18 to 22 AWG wire, with ends
stripped approximately 6mm (1/4 in.) Use the
appropriate wiring method as shown in these diagrams:
2341
ON
V+
V-
NC
C
NO
EOL
S4
TMPR
TMPR
EOL
FG-1625T Only
1625Wiring_001-V0
Normally Closed Loop/No EOL Resistor
2341
ON
V+
V-
NC
C
NO
EOL
S4
TMPR
TMPR
EOL
FG-1625T Only
1625Wiring_002-V0
Normally Open Loop/No EOL Resistor
2341
ON
V+
V-
NC
C
NO
EOL
S4
TMPR
TMPR
EOL
FG-1625T Only
1625Wiring_003-V0
Normally Closed Loop/With EOL Resistor
2341
ON
V+
V-
NC
C
NO
EOL
S4
TMPR
TMPR
EOL
FG-1625T Only
1625Wiring_004-V0
Normally Open Loop/With EOL Resistor
Mount Detector
Place unit over wall tamper screw, if used!
Use mounting holes as template to mark
ceiling or wall.
Mount detector using appropriate hardware.
1625_006-V00
2341
ON
Test Detector Installation
Enter Test Mode using FG-701 (see Testing the
Detector on the next page) or manually by shorting
THE Test Mode pads (as below).
TEST
1625_007-V1
2341
ON
Install Cover Screw (optional)
1625_008-V1
2.2 m
m
(#4) screw,
6 m
m
(1/4-in.) long
Question and Answer IconNeed help?

Do you have a question about the Honeywell FlexGuard FG-1625 and is the answer not in the manual?

Honeywell FlexGuard FG-1625 Specifications

General IconGeneral
BrandHoneywell
ModelFlexGuard FG-1625
CategorySecurity Sensors
LanguageEnglish

Summary

FG-1625/FG-1625T Glassbreak Detector

Enable Wall Tamper (FG-1625T only)

Instructions for enabling the wall tamper switch on the FG-1625T model.

Mount Detector

Steps for mounting the glassbreak detector unit onto a wall or ceiling.

Select Mounting Location

Test Location w/ 9V Battery

Set Sensitivity & LED Configuration

Configure Sensitivity

Adjusting detector sensitivity using SENS1 and SENS2 DIP switches.

Configure LED Indicator

Setting LED behavior using LATCH and LED DIP switches.

Connect Detector

Detector Wiring Methods

Diagrams illustrating various wiring configurations for the detector.

Test Detector Installation

Install Cover Screw

General Information

Choosing Mounting Location

Enabling Optional Rear Tamper (FG-1625T only)

Mounting the Detector

Wiring the Detector

Testing the Detector

Test Mode Entry

Procedures for entering Test Mode manually or using the FG-701 simulator.

Flex and Audio Signal Testing

Testing detector response to flex and audio signals with the FG-701.

Audio Signal Only Testing

Testing the detector's response to audio signals alone.

Exiting Test Mode

Methods for exiting the detector's Test Mode.

LED Indicators

Cover Screw

Remote LED Enable/Disable Mode

Nominal Glass Thickness Chart

Specifications

Notices

FCC Notice

Information regarding FCC compliance and potential radio frequency interference.

IC Notice

Information regarding Canadian Interference-Causing Equipment Regulations.

Related product manuals