HE220, HE260 HUMIDIFIER AND INSTALLATION KIT
69-2516EF—01 6
IMPORTANT
With low-speed airflow or variable speed sys-
tems it is recommended to run tubing to both the
supply and return ducts.
Fig. 12. Install tubing.
8. You may cut the tubing to fit the connection length
between the elbow fitting and switch. It is also rec-
ommended to secure the hose to existing structures
to avoid accidental disconnection.
Installing the Humidistat
Installing on Mounting Duct
1. Apply the template to the duct location chosen
for the humidistat. Make sure the template is
level before drilling the holes.
2. Refer to the template (provided with the H8908
Humidistat Installation Instructions) to drill the
control assembly opening and mounting holes
for the H8908.
3. Remove the H8908 case from the base.
4. Position the foam gasket on the H8908 base.
5. Position the base on the duct with the arrow up.
6. Secure the base to the duct using the four
1 in. (25 mm) mounting screws provided with humi-
distat.
7. Connect the low-voltage wires to the leads and
replace the H8908 case. See Fig. 14.
NOTE: For wall mounting instructions, see the H8908
Installation Instructions.
Fig. 13. Humidistat base and rear view.
WIRING
CAUTION
Hazardous Voltage.
Can cause personal injury or equipment
damage.
Disconnect power supply before installing or
servicing equipment.
IMPORTANT
All wiring must comply with applicable local
code, ordinances and regulations.
Wire the humidifier solenoid valve, pressure switch,
humidistat and transformer. See Fig. 15.
Fig. 14. Wiring the controls.
Fig. 15. Close-up of pressure switch wiring.
1. Run the two-strand thermostat wire from the humid-
ifier to the humidistat, and from the humidistat to the
pressure switch and back to complete the wiring
loop to the humidifier. This is illustrated in Fig. 14.
2. Cut lengths of thermostat wire to reach between
components, leaving adequate wire at both ends for
connections.
NOTE: Humidistat and pressure switch can be wired in
any order.
3. At the humidifier, connect the black and white con-
ductors to the two black humidifier wires.
4. At the transformer, connect both black conductors
to the two transformer terminals. Use a wire nut to
connect together the two white conductors.
M27304
INSIDE
OF DUCT
CONNECT TUBING TO + CONNECTION IF PRESSURE TAP IS
MOUNTED TO SUPPLY DUCT. CONNECT TO – IF PRESSURE
TAP IS MOUNTED TO RETURN DUCT.
1
1
M28974
HUMIDIFIER
SOLENOID
VALVE
H
u
m
id
i
t
y
C
o
n
t
r
o
l
R
é
g
u
la
t
e
u
r
d
'h
u
m
i
d
i
t
é
-
2
0
¡F
-
1
0
¡
F
0
¡F
+
1
0
¡
F
+
2
0
¡
F
O
ve
r 2
0
¡
F
1
5
%
2
0
%
25
%
3
0
%
3
5%
4
0
%
H
U
M
I
D
IT
Y
S
E
T
T
I
N
G
O
U
TD
O
O
R
TE
M
P
E
R
ATU
R
E
-
3
0
¡
C
-25
¡
C
-
2
0
¡
C
-1
0
¡
C
-
5
¡C
O
v
er
0
¡C
HUMIDISTAT
AIR PRESSURE
SWITCH
TRANSFORMER
ATTA CH
ADAPTOR
WIRE TO HVAC
C TERMINAL
M27398A
COMMON (C) TERMINAL
1/4 (6) X 1/32 (1) THICK
QUICK CONNECT
NORMALLY OPEN (NO)
TERMINAL 1/4 (6) X 1/32 (1)
THICK QUICK CONNECT
ATTACH ADAPTER
WIRE TO HUMIDIFIER
C TERMINAL
C
1
2
3
1
2
3
2
3
NC
NO
+
PI
ASSEMBLED
IN MEXICO

Other manuals for Honeywell HE220

Related product manuals