EasyManua.ls Logo

Honeywell HE240 - Determining Best Location for Humidifier; Typical humidifier installation locations

Honeywell HE240
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HE240, HE280 HUMIDIFIER AND INSTALLATION KIT
5 69-2686EF—01
Determining Best Location for Humidifier
Select a location for the humidifier on the supply (warm air stream) duct. See Fig. 1
for examples. Return duct mounting is acceptable if there are space restrictions on
the supply duct. If you are mounting the humidifier on the return duct, simply swap
“return duct” for “supply duct” throughout these instructions.
Select a location that cannot damage the air conditioner A-coil during installation.
Do not locate the humidifier on the furnace body.
Mount the humidifier in a conditioned space to prevent freezing.
Mount the humidifier at least 3 in. (78 mm) above the furnace body to allow
adequate space for the solenoid valve and drain line.
Fig. 1. Typical humidifier installation locations.
M12248D
HORIZONTAL
DOWN
FLO
LOWBOY
HIGHBOY
HUMIDIFIER
BYPASS
COLLAR
69-2686EF_A.book Page 5 Friday, March 9, 2012 11:37 AM