EasyManua.ls Logo

Honeywell HE260 - Humidifier Wiring Instructions; Hazardous Voltage Safety Warning; Wiring the Humidifier Controls

Honeywell HE260
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HE220, HE260 HUMIDIFIER AND INSTALLATION KIT
17 69-2634EF—01
Vacation
When leaving on vacation, turn off the humidifier water supply and your humidistat.
When you return, turn on the humidifier water supply and reset your humidistat.
CHECKING YOUR HUMIDIFIER FOR
CORRECT OPERATION
After winter startup or servicing, use the following steps to check your humidifier
operation:
1. Turn on the humidifier power and water supply.
2. Turn the humidistat to its highest setting and set the thermostat to 10°F (6°C)
above the room temperature.
3. Observe that water is flowing out of the drain hose.
NOTE: The furnace blower must be running to activate the humidifier.
4. Reset the thermostat and humidistat to a comfortable setting for automatic oper-
ation.
TROUBLESHOOTING YOUR HUMIDIFIER
Table 3. Troubleshooting Humidifier.
Problem What to look for What to do
Water leakage Leaking joints. Shut off water.
Tighten connections.
Brass tubing inserts Verify that brass tubing inserts are used.
Saddle valve leaking. Verify rubber pad is installed on saddle
valve.

Other manuals for Honeywell HE260

Related product manuals