11. Assemble the summer shutoff
damper into the starter collar.
Verify that the damper rotates
freely between the open and
closed positions. Make sure the
handle is accessible. Mark the
damper Closed position as Sum
-
mer and the Open position as
Winter. See Fig. 6.
12. Remove liner to expose foam
adhesive. Position starter collar
over opening.
13. Slide one end of the flexible duct-
ing over the starter collar and
secure with one of the connecting
straps.
Fig. 6. Installing the starter collar.
14. Insert the plain collar
into the humidifier port
and secure with sheet
metal screws. Con
-
nect the flexible duct-
ing over the collar and
secure with a con
-
necting strap. See
Fig. 7.
15. Seal the duct connec-
tions with duct tape
(not included).
16. Reinstall the humidi-
fier pad assembly in
the humidifier hous
-
ing.
17. Hinge the cover in
place and secure with
the thumbscrew
located at the bottom
of the cover.
Fig. 7. Connecting bypass ducting.
SUMMER
WINTER
M20173
M20785
PLAIN COLLAR
HUMIDIFIER PORT