IMPORTANT SAFETY
INSTRUCTIONS
READ AND SAVE THESE
SAFETY INSTRUCTIONS
BEFORE USING THIS AIR
PURIFIER
When using electrical appliances, basic
precautions should always be followed to
reduce the risk of fire, electric shock, and
injury to persons, including the following:
1. Read all instructions before operating the air
purifier.
2. Place air purifier where it is not easily knocked
over by persons in the household.
3. Always turn the air purifier controls to the OFF
position and unplug from the wall outlet when
not in use.
4. To disconnect the model HFD-120 series air
purifier, press the Power button to turn the unit
off, grip the plug and pull it from the wall
outlet. Never pull by the cord.
5. Do not use any product with a damaged cord
or plug or if product malfunctions, is dropped
or damaged in any manner. Keep the cord
away from heated surfaces.
6. Do not use air purifier outdoors.
7. Never use air purifier unless it is fully
assembled.
8. Do not run power cord under carpets, and do
not cover with throw rugs. Arrange cord such
that it will not be tripped over.
9. Do not use air cleaner where combustible
gases or vapors are present.
10. Do not expose the air purifier to rain, or use
near water, in a bathroom, laundry area or
other damp location.
11. The air purifier must be used in its upright
position.
12. Do not allow foreign objects to enter ventilation
or exhaust opening as this may cause electric
shock or damage to the air purifier. Do not
block air outlets or intakes.
13. Locate air purifier near the outlet and avoid
using an extension cord.
14. This appliance has a polarized plug (one blade
is wider than the other). To reduce the risk of
shock, this plug is intended to fit only one way
in a polarized outlet. If the plug does not fit
fully in the outlet, reverse the plug. If it still
does not fit, contact a qualified electrician.
DO NOT attempt to defeat this safety feature.
15. A loose fit between the AC outlet (receptacle)
and plug may cause overheating and a
distortion of the plug. Contact a qualified
electrician to replace loose or worn outlet.
16. Do not sit, stand or place heavy objects on the
air purifier.
17. Disconnect power supply before servicing.
WARNING: To Reduce The Risk of Fire or
Electric Shock, Do Not Use This Air Purifier
With Any Solid-State Speed Control Device.
OSCILLATING
IFD
TOWER
AIR PURIFIER
For Model Series
HFD-120
HFD-120_OM_Rev0.qxd 9/22/05 5:05 PM Page 1

Other manuals for Honeywell HFD-120 Series

Question and Answer IconNeed help?

Do you have a question about the Honeywell HFD-120 Series and is the answer not in the manual?

Honeywell HFD-120 Series Specifications

General IconGeneral
Product TypeAir Cleaner
Model SeriesHFD-120
Filter TypeHEPA
CADR (Smoke)100
CADR (Dust)110
Filtration Stages3
Pre-filterYes
Activated Carbon FilterYes
Number of Speeds3
Voltage120V
TypeTower
Noise Level50 dB
Power Consumption55 Watts

Summary

Important Safety Instructions

Read and Save Safety Instructions

Read and save all safety instructions before initial use of the air purifier.

General Safety Precautions

Follow basic precautions to reduce risk of fire, electric shock, and injury when using electrical appliances.

Specific Safety Warnings

Covers cord safety, environment, placement, electrical plug use, and avoiding damage or misuse.

How Your Air Purifier Works

3-Stage Cleaning System Overview

Explains the three stages of air purification: pre-filter, IFD filter, and ionizer.

Stage 1: Washable Pre-Filter

The first stage captures larger airborne particles from the air.

Stage 2: Permanent Washable IFD™ Filter

The second stage utilizes a permanent, washable IFD filter for advanced cleaning.

Stage 3: Electronic Ionizer

The third stage employs an electronic ionizer to further purify the air.

Set-Up Instructions

Location and Airflow Requirements

Position the unit on a firm, level surface, at least 3 feet from walls or furniture for proper airflow.

Maintaining Surrounding Areas

Keep the area around the purifier clean to prevent dust buildup and prolong filter life.

Operating Your Air Purifier

Powering On and Adjusting Speed

Plug in the unit and use the power button to start and change cleaning speeds.

Recommended Usage Conditions

Run 24 hours a day in rooms with closed doors and windows for best results.

Electronic Filter Clean Reminder

Resetting the Filter Indicator

Reset the filter monitor light by pressing a button near the LED after cleaning filters.

Oscillation Feature

Activating Oscillation

Press the Oscillation button to activate the feature for circulating air.

Filter Maintenance

Removing the IFD™ Filters

Instructions on how to safely remove the IFD™ filters from the air purifier.

Cleaning the IFD™ Filters

Detailed steps for vacuuming, washing, and drying IFD™ filters.

IFD™ Filter Cautions

Important warnings regarding wet filters, dishwasher use, and cleaning agents.

Pre-Filter Cleaning and Unit Care

Cleaning the Pre-Filter

Rinse the particle pre-filter by hand under warm water and allow to dry completely.

Cleaning and Storage

Wipe external surfaces with a dry cloth; do not use water or chemical solutions.

Frequently Asked Questions

Cleaning Frequency

Clean IFD™ filters about every four weeks, or wash when needed but not more than monthly.

Optimal Run Time

For best results, operate the air purifier 24 hours a day with doors and windows closed.

Accessories and Replacement Filters

Ordering Replacement Filters

Order replacement filters via website www.kaz.com or by calling 1-800-477-0457.

Consumer Relations and Support

Contact Information

Contact Kaz, Inc. for questions, comments, or warranty issues via mail, phone, or website.

Important Note on Returns

Contact consumer relations first for problems; do not attempt to open the motor housing yourself.

5 Year Limited Warranty

Warranty Coverage and Limitations

Covers material/workmanship defects for 5 years, excluding damage from misuse or normal wear.

Repair or Replacement Process

Defective products may be repaired or replaced by Kaz at their option.

Exclusions from Warranty

Warranty does not cover unauthorized repairs, misuse, or IFD™/pre-filter defects unless material/workmanship related.

Returning Defective Products

Instructions for returning defective products to Kaz, Inc. in the US and Canada, including required documentation and fees.