System Operation
LOW BAT with no zone number
indicates that the systems backup battery is weak.
LOW BAT
with a zone number
and a once-per-45 seconds beeping at the keypad indicates that a
low battery condition exists in the wireless sensor displayed (zone 00 indicates a wireless button/keypad).
If the battery is not replaced within 30 days, a FAULT display may occur.
Fault Zone 93
, along with a flashing
AC
and a once per 45-seconds beeping at the keypad indicates a loss of
AC power to the 5842 Wireless Dialer (if this feature is supported by the Wireless Dialer being installed).
Fault Zone 93
, along with a single beep indicates that setup information from the 5842 Wireless Dialer has not
been properly received.
Power Failure
If there is no display at all, and both indicators are not lit,
operating power for the system has
stopped and the system is inoperative.
If the display is lit and the AC display is off,
the system is operating on battery power only.
During an AC power loss,
the backlighting will turn off and the indicators will flicker slightly to
minimize deep discharge of the battery.
Other Displays
dI = Busy-Standby
: Displayed upon power-up. After approximately 1 minute* the green READY LED
should light. If the
dI
remains displayed for more than 1 minute, the system is disabled.
*To bypass the 1-minute delay, press [#] + [0]. Important: Do not try to bypass 1 minute delay before
dI
is displayed!
CC
=
Modem Comm:
The system is communicating with the central station for change of function or
status verification.
FC = Comm. Failure:
A communication failure has occurred. This message clears only when the system
is subsequently armed.
90 = RF Jam:
The system has detected an RF jamming condition or excessive interference.
93 =
PH = Speaker Phone Mode:
The system is in Speaker Phone mode.
PC = Phone Control:
The remote Phone Control feature is active.

Other manuals for Honeywell LYNXR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell LYNXR and is the answer not in the manual?

Honeywell LYNXR Specifications

General IconGeneral
BrandHoneywell
ModelLYNXR
CategorySecurity System
LanguageEnglish

Related product manuals