LYRIC T6 SMART THERMOSTAT
LYRIC-T6-EN0H 8603 NL01 R1216
DIMENSIONS
Menu item
Default
Options
Language
English
English, Francais, Espanol, Deutsch, Nederlands, Italiano
OpenTherm
-
OpenTherm boiler data when a vailable
Cycle rate
6
3,6,9 or 12
Min on time
1 minute
1, 2, 3, 4 or 5 minutes
Heat range
Min = 5.0
Max = 37.0
Min: 5.0°C to 21.0 °C, Max:21.0°C to 37.0 °C
Schedule options
Daily
1 = daily schedule, 2 = 5+2 days schedule
External sensor
no sensor
0 = no sensor, 1 = external room sensor
Optimisation
Opt.start on
Opt.stop off
Opt start: 0 = off, 1 = on, 2 = Delayed start
Opt stop: 0 = off, 1 = on
Clock
Format: 24h
Time: --:--
Date:
01/09/2016
Clock format: 1 = 12h, 2 = 24h
Setup time and date
Low Load Control
ON
0= Off, 1 = On
Temperature offset
0.0
-1.5°C to 1.5 °C
Bind
-
Bind, check RF and clear bind.
Adv Reset
-
Factory, schedule, Wi-Fi and Homekit reset
Failsafe
OFF
0= Off, 1 = On
LYRIC T6
LYRIC T6R
RECEIVER BOX
PACKAGING